EUTECNIQ Sciences

See every page on one mapArrow keys move through results · Enter opens · Esc closes

Digital lab and traceability Proposed capability

Every result would trace back to its sample, method, analyst and lot, and every change would leave a record

How a proposed laboratory information management system (LIMS), the U.S. data-integrity rules behind it, lot genealogy and a tamper-evident record chain would connect each number on a certificate of analysis to its origin.

Related: CFR atlas · Quality and Six Sigma · Course 6: certificate-of-analysis science

11lettered controls for closed systems, 21 CFR 11.10(a)–(k)
9ALCOA+ data-integrity attributes, PIC/S PI 041-1 (2021)
7critical tracking events in the FSMA 204 traceability rule
24 hto give FDA traceability records on request, 21 CFR 1.1455(c)
Jul 20, 2028no FSMA 204 enforcement before this date, Public Law 119-37 § 780

Status. EUTECNIQ has no laboratory, software, data or customers. This page describes a proposed design and the rules it would follow. No system has been selected or purchased, and no product is named.

Sample lifecycle and chain of custody

Each sample would keep one identifier from receipt to disposal, and each change of state would write a record

Ten recorded states of a sample: select a state, or let the sample move through the laboratoryProposed workflow; rules cited
  1. 1. Receive. Chain-of-custody entry, container condition and any deviation from specified conditions. ISO/IEC 17025 7.4.1 and 7.4.3; 21 CFR 111.155(a)
  2. 2. Log in. Unique sample ID linked to the lot, supplier, date received and status (quarantined). 21 CFR 111.155(d)(1); ISO/IEC 17025 7.4.2
  3. 3. Store. Storage location and condition; every transfer of custody. ISO/IEC 17025 7.4.1
  4. 4. Split. Aliquots and reserve portions get their own IDs, linked to the parent sample. ISO/IEC 17025 7.4.2 (sub-division); 21 CFR 111.83 (reserve samples of packaged lots)
  5. 5. Test. Raw data, method version, instrument ID, user, date and time, saved at each step. 21 CFR 111.325(b)(2); FDA data-integrity Q&A (2018), question 12
  6. 6. Review. A second person reviews the results and the audit trail that captured changes to them. 21 CFR 111.110(c); FDA data-integrity Q&A (2018), question 7
  7. 7. Check. Result compared with the specification, with stated rounding and a documented decision rule. 21 CFR 111.70; ISO/IEC 17025 7.8.6
  8. 8. Approve. Quality control decides disposition; the electronic signature shows name, date and time, and meaning. 21 CFR 111.87, 111.140(b)(2) and 11.50
  9. 9. Report. Certificate generated from the approved record, with a unique report ID. ISO/IEC 17025 7.8.2.1; 21 CFR 111.75(a)(2)(ii)(B)
  10. 10. Retain. Records kept for the retention period; the sample returned or disposed of, with a record. 21 CFR 111.605(a); ISO/IEC 17025 7.4.1

Audit trail written so far (simulated)

    eCFR, 21 CFR Parts 11 and 111, current to Oct 22, 2026; ISO/IEC 17025:2017, clauses 7.4 and 7.8 (as quoted by PJLA and NIST OWM); FDA, Data Integrity and Compliance With Drug CGMP Q&A (Dec 2018).

    Ten recorded states: the analyst, the reviewer and quality control would each sign their own step, and the system would write the audit trail.

    Explanation, details and sources

    Chain of custody is the unbroken record of who held a sample, where and in what condition, from receipt to disposal. ISO/IEC 17025:2017 asks a laboratory for a procedure covering transport, receipt, handling, storage, retention and disposal (7.4.1), and for unambiguous identification retained while the item is in its care, including sub-divisions (7.4.2). Part 111 asks a supplement manufacturer to identify each unique lot of components so it can be traced to the supplier, the date received, its status and the products it went into (21 CFR 111.155(d)(1)).

    The steps are a proposed design. Roles follow Part 111: quality control personnel review and approve test results (111.110(c)) and make disposition decisions (111.87), and their review is documented with date and signature at the time of performance (111.140(b)(2)). With motion allowed the sample moves by itself; under reduced motion use the buttons.

    Instrument to certificate

    Results would move from instrument to certificate without retyping, carrying the metadata that gives them meaning

    Proposed data flow: capture with metadata, check, approve, report, with an audit trail underneathProposed design, not to scale
    Proposed data flow: instrument results would be captured with their metadata, checked against the specification in the LIMS, approved with an electronic signature and printed on the certificate without retyping; an audit trail would record every changeInstrumentsAcquisition recordLaboratory information systemRelease and certificateBalance, pH meterprintout can be the original recordHPLC, LC-MSdynamic: injections, integration,reprocessingFT-IR, NIRdynamic spectral file that can bereprocessedICP-MS, GC-MSdata file with its acquisition methodPlate countscontemporaneous count,second-person reviewSaved at each stepuser IDdate and timeinstrument IDmethod and versionprocessing parametersaborted runs keptreprocessed results keptreason for each changeFDA Q&A 1.b, 12, 14Sample and lot registryone ID per sample, linked to the lotTests from the specificationassigned automatically, by versionResults and calculationsimported, not retypedSpecification checkstated rounding and decision ruleReview and approvalsecond person; e-signature withmeaningQuality control releaseQC personnel decidedisposition (§ 111.87)Certificate of analysisgenerated from the approvedrecordCustomer or next siteoptional: hash of the certificateAudit trail, written by the system for every entry and changewho · what · when · old value · new value · reason; changes never overwrite earlier entries (§ 11.10(e))Not to scale. Instrument types are examples of record formats named in FDA's 2018 Q&A (static printouts, dynamic chromatography and FT-IR files) and in the planned scope; novendor or product is implied.
    FDA, Data Integrity Q&A (Dec 2018), questions 1.b, 1.c, 10, 12 and 14; 21 CFR 11.10(e) and 111.87; ISO/IEC 17025:2017, 7.11.2 (LIMS validated before use) and 7.11.6 (calculations and data transfers checked).
    FDA's example: “23” means nothing until its metadata says 23 mg, when, by whom, on which instrument, for which lotFDA guidance
    FDA's own example: the number 23 means nothing until its metadata says 23 mg, when it was acquired, by whom, on which instrument, for which material, and what was changed23a data valueunitmgdate/time stampwhen acquireduser IDwho ran the testinstrument IDwhich systemmaterial ID numberwhich lotmaterial statuse.g., quarantinedaudit trailwhat changed, whenmethod versionhow measuredFDA's HPLC audit-trail example1user name2date and time of the run3integration parameters used4details of any reprocessing5the justification for reprocessingThe audit trail should let a reviewer reconstruct how theresult was produced.
    FDA, Data Integrity and Compliance With Drug CGMP: Questions and Answers, guidance for industry (Dec 2018), questions 1.b (metadata) and 1.c (audit trail). Nonbinding; written for drug CGMP (21 CFR 210, 211, 212). “Method version” is added by this page.
    What a certificate of analysis would contain, and which rule or standard asks for each lineRegulation Standard text
    Anatomy of a certificate of analysis: the contents ISO/IEC 17025 requires in a report, and the three elements a Part 111 buyer needs before relying on a supplier certificate: method, limits and actual resultsCertificate of analysis (schematic)Title, unique report ID on every page, clear end of report17025 7.8.2.1 a, dLaboratory name and address; test location if different17025 7.8.2.1 b, cCustomer17025 7.8.2.1 eItem: description, sample ID, lot identifier, condition17025 7.8.2.1 g§ 111.155(d)Dates: sampled (where critical), received, tested, issued17025 7.8.2.1 h, i, jReference to the sampling plan and method17025 7.8.2.1 kEach test: method, limit, actual result, unit17025 7.8.2.1 f, m§ 111.75(a)(2)(ii)(B)Conformity statement and the decision rule used17025 7.8.6Results relate only to the items tested17025 7.8.2.1 lWho authorized it; e-signature shows name, date and time, meaning17025 7.8.2.1 o§ 11.50A correction is a new, identified report that references the original17025 7.8.8ISO/IEC 17025:2017 report content21 CFR 111 (supplement cGMP)21 CFR 11 (electronic signatures)A Part 111 firm may rely on a supplier certificate for components other than dietary ingredients only after qualifying the supplier; each dietary ingredient still needs atleast one identity test (§ 111.75(a)).
    ISO/IEC 17025:2017, 7.8.2.1, 7.8.6 and 7.8.8 (NIST OWM crosswalk, Feb 2018); eCFR, 21 CFR 111.75(a), 111.155(d) and 11.50, current to Oct 22, 2026.

    A number without its unit, time, user, instrument and audit trail is incomplete; dynamic files such as chromatograms and FT-IR spectra would be kept, not printouts.

    Explanation, details and sources

    FDA's 2018 Q&A defines metadata as the contextual information required to understand data, and an audit trail as a secure, computer-generated, time-stamped record that allows the course of events around a record to be reconstructed. A balance or pH-meter printout can be the original record; an FT-IR spectral file is dynamic and can be reprocessed, so a printout of it is not a true copy (question 10). Chromatographic data should be saved at each step or injection, aborted runs captured in the audit trail, and every reprocessed result kept (questions 12 and 14).

    ISO/IEC 17025:2017 requires a LIMS to be validated for functionality, including its interfaces, before use (7.11.2), protected from unauthorized access, tampering and loss (7.11.3), and calculations and data transfers to be checked (7.11.6). A conformity statement needs a documented decision rule (7.8.6), and a corrected report is a new, identified report that references the original (7.8.8).

    Under Part 111, a firm may rely on a supplier's certificate for components other than dietary ingredients only if it first qualifies the supplier by confirming the certificate's results, the certificate describes the methods, limits and actual results, and the qualification is documented, periodically re-confirmed and approved by quality control (21 CFR 111.75(a)(2)(ii)(A)–(E)). Each dietary-ingredient lot still needs at least one identity test (111.75(a)(1)(i)).

    21 CFR Part 11

    Part 11 would govern the electronic supplement-cGMP records, and FDA still enforces its access, signature and accountability controls

    Part 11 has 61 lowest-level paragraphs; scope exclusions and the eleven closed-system controls are the largest blocksRegulation text, counted
    eCFR, 21 CFR Part 11, current to Oct 22, 2026; paragraphs counted at their lowest level by this page. Select a ring to zoom; select the centre to zoom out.
    Data table: paragraphs per section
    21 CFR Part 11 paragraphs counted at the lowest level
    SectionTitleParagraphs
    11.1Scope (11 of 16 are exclusions, (f) to (p))16
    11.2Implementation3
    11.3Definitions10
    11.10Controls for closed systems12
    11.30Controls for open systems1
    11.50Signature manifestations4
    11.70Signature/record linking1
    11.100Electronic signatures: general requirements4
    11.200Electronic signature components and controls5
    11.300Controls for identification codes and passwords5
    Total (Subpart A 29, Subpart B 18, Subpart C 14)61
    Which records Part 11 covers in a site that makes both supplements and ingredientsRegulation
    Part 11 covers the electronic Part 111 records of a supplement operation; Part 117 and FSMA 204 records are exempt unless another rule also requires themRecord typeRulePart 11Where the rule says soDietary-supplement cGMP records21 CFR 111applies“All electronic records must comply with part 11”(§ 111.605(c))Ingredient preventive-controls records21 CFR 117exemptExempt from Part 11 (§ 11.1(i); § 117.305(g))Food-traceability records (FSMA 204)21 CFR 1, Subpart SexemptExempt from Part 11 (§ 1.1455(e))A record another rule also requiresPart 117 or Subpart SappliesRemains subject to Part 11 (§ 11.1(i); § 1.1455(e))Electronic records submitted to FDAFD&C ActappliesCovered even if no regulation names them (§ 11.1(b))
    eCFR, 21 CFR 11.1(b) and (i), 111.605(c), 117.305(g) and 1.1455(e), current to Oct 22, 2026.
    FDA set aside four § 11.10 controls in 2003 and kept enforcing the rest and every signature ruleRegulation FDA guidance
    FDA's 2003 guidance set aside enforcement of validation, copies, retention and audit-trail requirements of § 11.10 and kept enforcing access, checks, training, accountability, documentation and every electronic-signature requirement; predicate rules still applyFDA intends to enforce (2003 guidance)Enforcement discretion since 2003; predicate rules still applySystem validation§ 11.10(a) · accuracy,reliability, ability todiscern altered recordsComplete copies§ 11.10(b) ·human-readable andelectronic, for FDAreviewRecord protection§ 11.10(c) · ready retrievalthrough the retentionperiodAccess limited§ 11.10(d) · authorizedindividuals onlyAudit trails§ 11.10(e) · secure,time-stamped; changesdo not obscure entriesOperational checks§ 11.10(f) · enforce thepermitted sequence ofstepsAuthority checks§ 11.10(g) · who may sign,alter or operateDevice checks§ 11.10(h) · validity of thedata sourceTrained people§ 11.10(i) · education,training, experienceAccountability policy§ 11.10(j) · deters recordand signaturefalsificationDocumentationcontrol§ 11.10(k)(1) · distribution,access and useChange-control trail§ 11.10(k)(2) ·time-sequenced historyof system documentsOpen systems§ 11.30 · § 11.10 plusencryption, digitalsignaturesSignature shows§ 11.50 · name, date andtime, meaningSignature linked§ 11.70 · cannot beexcised or copiedOne person, verified§ 11.100 · unique; identitychecked; FDAcertificationTwo components§ 11.200 · e.g., ID codeand passwordPassword controls§ 11.300 · uniqueness,aging, loss, safeguards,testingEvery control would be implemented in the proposed system whatever FDA's enforcement position.FDA's 2003 guidance set aside enforcement of validation, copies, retention and audit-trail requirements of § 11.10 and kept enforcing access, checks, training, accountability, documentation and every electronic-signature requirement; predicate rules still applyFDA intends to enforceEnforcement discretion (2003)System validation§ 11.10(a) · accuracy,reliability, ability todiscern altered recordsComplete copies§ 11.10(b) ·human-readable andelectronic, for FDA reviewRecord protection§ 11.10(c) · ready retrievalthrough the retentionperiodAccess limited§ 11.10(d) · authorizedindividuals onlyAudit trails§ 11.10(e) · secure,time-stamped; changesdo not obscure entriesOperational checks§ 11.10(f) · enforce thepermitted sequence ofstepsAuthority checks§ 11.10(g) · who may sign,alter or operateDevice checks§ 11.10(h) · validity of thedata sourceTrained people§ 11.10(i) · education,training, experienceAccountability policy§ 11.10(j) · deters recordand signature falsificationDocumentation control§ 11.10(k)(1) · distribution,access and useChange-control trail§ 11.10(k)(2) ·time-sequenced history ofsystem documentsOpen systems§ 11.30 · § 11.10 plusencryption, digitalsignaturesSignature shows§ 11.50 · name, date andtime, meaningSignature linked§ 11.70 · cannot beexcised or copiedOne person, verified§ 11.100 · unique; identitychecked; FDA certificationTwo components§ 11.200 · e.g., ID codeand passwordPassword controls§ 11.300 · uniqueness,aging, loss, safeguards,testingEvery control would be implemented in the proposed systemwhatever FDA's enforcement position.
    eCFR, 21 CFR 11.10–11.300; FDA, Part 11, Electronic Records; Electronic Signatures: Scope and Application, guidance (Aug 2003), sections III.A and III.C.1–5.
    A Part 11 electronic signature shows who, when and what it means, and stays bound to its recordRegulation
    Anatomy of a Part 11 electronic signature: the signed record shows the signer's printed name, the date and time and the meaning; the signature is linked to the record; it uses two components and belongs to one verified personResult record: assay of a hypothetical lotSigned by: [printed name of the signer]Date and time: [yyyy-mm-dd hh:mm, time zone]Meaning: approval for release§ 11.50(a)(1)–(3)printed name, date and time, meaning§ 11.50(b)shown on screen and on every printout§ 11.70linked so it cannot be cut, copied ormoved to another recordBefore a signature is issued§ 11.100(a)unique to one person; never reused orreassigned§ 11.100(b)the person's identity is verified first§ 11.100(c)the firm certifies to FDA that signatures arelegally bindingEach time a person signs§ 11.200(a)(1)two components, such as ID code andpassword; the first signing in a session usesboth§ 11.200(a)(3)misuse would need two or more people tocollude§ 11.300: ID-code and password controls (uniqueness, periodic revision, loss management, transaction safeguards,device testing).
    eCFR, 21 CFR 11.50, 11.70, 11.100, 11.200 and 11.300, current to Oct 22, 2026. Schematic; placeholder text, not a real record.

    Section 111.605(c) brings Part 11 to every electronic Part 111 record; Part 117 and FSMA 204 records are exempt unless another rule also requires them.

    Explanation, details and sources

    Part 11 sets the criteria under which FDA treats electronic records and signatures as trustworthy and equivalent to paper (11.1(a)). It applies to electronic records kept under any FDA records requirement (11.1(b)); Part 111 states that all electronic records must comply with it (111.605(c)). Records required only by Part 117 or by the food traceability rule are exempt (11.1(i), 117.305(g), 1.1455(e)).

    In its 2003 guidance FDA said it would interpret Part 11 narrowly and would not enforce its validation, audit-trail, record-retention and record-copying requirements (11.10(a), (b), (c), (e) and (k)(2)) while it re-examined the rule, but that predicate-rule requirements still apply and that it would keep enforcing access limits, operational, authority and device checks, training, accountability policies, documentation controls and all electronic-signature requirements. The proposed system would implement every control regardless.

    Electronic signatures must be unique to one person (11.100(a)), issued after identity verification (11.100(b)) and certified to FDA as legally binding (11.100(c)); non-biometric signatures use at least two components such as an ID code and password (11.200(a)(1)).

    ALCOA+

    Each of the nine ALCOA+ attributes maps to specific U.S. rule text

    ALCOA+ matrix: attribute, meaning and the rule that expresses itGuidance Regulation
    ALCOA+ matrix: each of the nine attributes PIC/S defines has a counterpart in the U.S. rule text that a supplement and ingredient laboratory would followAttributeMeaning (PIC/S PI 041-1, 7.5)Where U.S. rule text expresses itAttributablewho did it, and who changed it, when andwhy§ 11.10(d), (g) access and authority checks; § 11.50 signer's name; § 111.260(j) initials ofeach person performing each stepLegiblereadable and unambiguous§ 11.10(b) human-readable copies; § 11.50(b) signature in every display; § 117.305(c);§ 1.1455(a)(2)Contemporaneousrecorded as it takes place§ 111.260(j)–(m) and § 111.325(b)(2)(i) “at the time of performance”; § 117.305(d)Originalthe first capture, or a true copy§ 111.605(b) original records, true copies or electronic records; § 1.1455(a)(1)Accuratea truthful representation of the facts§ 11.10(a) validation for accuracy; § 111.30(c) calibrate or check equipment; § 117.305(c)Completenothing critical lost; includes metadata§ 11.10(e) changes must not obscure earlier entries; § 111.260(h) results of any testConsistentdefined sequence, date formats, units,rounding§ 11.10(f) checks enforce the permitted sequence of steps and eventsEnduringintact for the whole retention period§ 11.10(c) protection through retention; § 111.605(a) retention periodAvailablereviewable at any time in that period§ 111.610(a) readily available to FDA; § 1.1455(c) within 24 hoursALCOA (FDA 2018 Q&A)the “+” attributes (PIC/S 2021)
    FDA, Data Integrity Q&A (Dec 2018), question 1.a; PIC/S PI 041-1, Good Practices for Data Management and Integrity in Regulated GMP/GDP Environments (in force Jul 1, 2021), sections 7.4–7.5; eCFR, 21 CFR Parts 11, 111, 117 and 1 Subpart S, current to Oct 22, 2026.

    FDA's 2018 Q&A names the first five (ALCOA) for drug CGMP; PIC/S adds complete, consistent, enduring and available. Both are guidance; the cited rule text is binding.

    Explanation, details and sources

    FDA defines data integrity as the completeness, consistency and accuracy of data, and says such data should be attributable, legible, contemporaneously recorded, original or a true copy, and accurate (ALCOA). The guidance is nonbinding and was written for drug CGMP (21 CFR 210, 211 and 212); it is used here because it defines the terms. PIC/S PI 041-1 adds four attributes (ALCOA+): complete, consistent, enduring and available, and lists chronological sequencing, date formats, units, rounding and significant digits as examples of consistency.

    The right-hand column quotes or paraphrases rule text a supplement and ingredient laboratory would follow; it does not claim that any rule uses the word “ALCOA”.

    Lot genealogy

    Lot genealogy would answer two recall questions at once: what went into this lot, and where did it go

    Select any lot: inputs light up upstream, and the recall scope lights up downstreamIllustrative, hypothetical lots
    what went into itwhere it went

    Root lot R-201 went into extract X-2, powder D-2, batch B-2, packaged lots K-2 and K-3, and reached customers 2 and 3.

    Hypothetical capsule product. Lot links required by 21 CFR 111.155(d)(1), 111.260(a), (d) and (e), 111.415(f) and 111.475(b)(2) (distribution records); eCFR current to Oct 22, 2026.
    Data table: every lot and what it was made from
    Hypothetical lot genealogy
    LotStageMade from or supplied by
    Root lots R-101, R-102Received lotGrower A
    Root lot R-201Received lotGrower B
    Ethanol E-01; maltodextrin M-01; capsules C-01; bottles and labels P-01Received lotsSolvent, carrier, capsule and packaging suppliers
    Extract X-1ExtractR-101, E-01
    Extract X-2ExtractR-102, R-201, E-01
    Powder D-1; powder D-2Dried powderX-1 and M-01; X-2 and M-01
    Batch B-1Finished batchD-1, C-01
    Batch B-2Finished batchD-1, D-2, C-01
    Packaged K-1; K-2 and K-3Packaged lotsB-1 and P-01; B-2 and P-01
    Customer 1; Customer 2; Customer 3ShipmentsK-1; K-1 and K-2; K-3

    Part 111 already requires each link; a lot database would make the backward and forward trace a query instead of a search through paper files.

    Explanation, details and sources

    Part 111 requires a unique identifier for each lot of components received or produced, traceable to the supplier, date received, status and the product made from it (111.155(d)(1)); a batch record listing the identifier and the weight or measure of each component used (111.260(d) and (e)); a lot number for each packaged and labeled lot from a finished batch (111.260(a), 111.415(f)); and records of product distribution (111.475(b)(2)). The figure joins those links. A backward trace answers which inputs, suppliers and tests stand behind a lot; a forward trace gives the scope of a recall.

    The lots, suppliers and customers are invented to show the method; they describe no real product or company.

    FSMA 204 food traceability

    FSMA 204 names fresh herbs, not dried herbs or supplements; its seven tracking events list 63 data elements

    Key data elements per critical tracking event: lot codes, locations and dates make up half; 20 also travel to the next recipientRegulation text, counted
    eCFR, 21 CFR 1.1325(a)–(b), 1.1330(a), 1.1335, 1.1340(a)–(b), 1.1345(a) and 1.1350(a), current to Oct 22, 2026; items counted and grouped by this page (“harvest origin” = field, container or fishing area, and the harvester's name and phone). Paths for sprouts (1.1330(b)), for food from exempt sources (1.1330(c), 1.1345(b)) and for retail are not shown.
    Data table: listed items per event and type
    FSMA 204 key data elements by critical tracking event
    Event (section)Lot code and sourceLocationsDatesQuantityProductReference documentHarvest originTotalAlso sent forward
    Harvesting (1.1325(a))021111287
    Cooling (1.1325(b))031111076
    Initial packing (1.1330(a))2242213160
    First land-based receiving (1.1335)201111170
    Shipping (1.1340(a))221111087
    Receiving (1.1345(a))221111080
    Transformation (1.1350(a))301221090
    Total11111099766320
    From Part 11 in 1997 to FSMA 204 enforcement in 2028Verified dates
    Timeline of the rules and guidance behind laboratory data integrity and food traceability, from Part 11 in 1997 to the FSMA 204 enforcement date of July 20, 2028Data integrity and traceability rules, 1997–20211996200020042008201220162020Part 11 effectiveAug 20, 1997Part 11 scope guidanceAug 2003Part 111 final ruleJun 25, 2007FSMA signedJan 4, 2011; § 204Part 117 final ruleSep 17, 2015FDA data-integrity Q&ADec 2018, drug CGMPPIC/S PI 041-1 (ALCOA+)Jul 1, 2021FSMA 204 food traceability rule, 2022–202820222023202420252026202720282029FSMA 204 final ruleNov 21, 2022Extension proposedAug 7, 2025: 30 monthsP.L. 119-37no enforcement before Jul 20, 2028Original compliance dateJan 20, 2026Enforcement dateJul 20, 2028
    62 FR 13464 (Mar 20, 1997); FDA Part 11 guidance (Aug 2003); 72 FR 34752 (Jun 25, 2007); Pub. L. 111-353 (Jan 4, 2011); 80 FR 55908 (Sep 17, 2015); FDA Q&A (Dec 2018); PIC/S PI 041-1 (Jul 1, 2021); 87 FR 70910 (Nov 21, 2022); 90 FR 38084 (Aug 7, 2025, proposed); Pub. L. 119-37, § 780 (Nov 12, 2025).

    The 2025 extension is still a proposed rule, but Congress barred enforcement before July 20, 2028. A botanical site would check each fresh input against the Food Traceability List.

    Explanation, details and sources

    The rule (21 CFR Part 1, Subpart S) applies to persons who manufacture, process, pack or hold foods on FDA's Food Traceability List (1.1300). The list names “Herbs (fresh)”, with parsley, cilantro and basil as examples, and covers foods that contain a listed food only while it stays in the listed form, such as fresh (FDA, Food Traceability List page, current as of Jul 24, 2026). The list does not name dried herbs, botanical extracts or dietary supplements; whether a given input is covered must be checked against the list.

    Covered firms keep a traceability plan (1.1315), assign traceability lot codes at initial packing, first land-based receiving and transformation (1.1320), keep the key data elements for each critical tracking event, provide records to FDA within 24 hours of a request, as an electronic sortable spreadsheet in an outbreak or recall unless a size exemption applies (1.1455(c)), and keep them for 2 years (1.1455(d)). The original compliance date was January 20, 2026. FDA proposed a 30-month extension (90 FR 38084), and Public Law 119-37, § 780 bars the use of funds to enforce the rule before July 20, 2028.

    Tamper-evident records

    A hash chain would make a later edit to a certificate or shipment record detectable; it cannot make the first entry true

    Live SHA-256 chain: change a value, then try re-sealing, and watch the shared final hash expose the rewriteDemonstration, hypothetical records
    Hashing runs in your browser (Web Crypto API, SHA-256 as specified in NIST FIPS 180-4). Records and values are invented. This demonstrates a technique; EUTECNIQ does not operate such a system.
    Text version of the demonstration

    Four records are sealed in order: batch B-2 closed (inputs D-1, D-2, C-01; yield 96.1 % of theoretical), finished-batch results (marker assay 2.4 % w/w; HPTLC identity conforms), the certificate for lot K-2 (specification met; approved by quality control with an e-signature) and the shipment of K-2 (Customer 2; 40 cases). Each record's hash covers its fields and the previous record's hash. Changing the assay in record 2 makes record 2 fail verification. Re-sealing records 2 to 4 makes every link verify again, but the final hash no longer matches the one shared with the customer, so the rewrite is still detected.

    How the chain works, what it detects and what it cannotSchematic
    How a hash chain works: each record's SHA-256 hash covers its own contents and the previous hash, so a later edit breaks every following link; it cannot show whether the first entry was true1. Receipt recordprevious hash = 000…0fields: lot, values, signerSHA-256(previous + fields)2. Test recordprevious hashfields: lot, values, signerSHA-256(previous + fields)3. Certificateprevious hashfields: lot, values, signerSHA-256(previous + fields)4. Shipment recordprevious hashfields: lot, values, signerSHA-256(previous + fields)final hash shared with the customer or time-stampedDetectsan edit to any record after it was sealeda deleted, inserted or reordered recorda rewrite of the whole chain, once the final hash was shared ortime-stamped (Haber and Stornetta 1991; RFC 3161)Does not detecta wrong or false value entered before sealing (NIST IR 8202, § 7.3)who entered it: that needs Part 11 access control and signaturesa record that was never entered
    Haber S, Stornetta WS. J Cryptology 1991;3:99–111; RFC 3161 (2001); NIST IR 8202 (2018), sections 7.1 and 7.3.
    SHA-256 offers 128-bit collision resistance; SHA-1 offers less than 80 bitsNIST data
    Security strengths of approved hash functions from NIST SP 800-107 Rev. 1, Table 1: SHA-256 gives 128-bit collision resistance and 256-bit preimage resistance; SHA-1 gives less than 80-bit collision resistance0100200300400500security strength (bits)SHA-1, collision resistance: 80SHA-1, preimage resistance: 160SHA-1SHA-224, collision resistance: 112SHA-224, preimage resistance: 224SHA-224SHA-256, collision resistance: 128SHA-256, preimage resistance: 256SHA-256SHA-384, collision resistance: 192SHA-384, preimage resistance: 384SHA-384SHA-512, collision resistance: 256SHA-512, preimage resistance: 512SHA-512< 80160112224128256192384256512collision resistancepreimage resistanceExpected collision strength is half theoutput length (L/2 bits); preimage strengthis the full length (L bits).The demonstration above uses SHA-256through the browser's Web Crypto API.
    NIST SP 800-107 Rev. 1 (Aug 2012), Table 1.
    Data table: security strengths in bits
    NIST SP 800-107 Rev. 1, Table 1 (selected functions)
    FunctionOutput lengthCollision resistancePreimage resistance
    SHA-1160< 80160
    SHA-224224112224
    SHA-256256128256
    SHA-384384192384
    SHA-512512256512

    No regulation requires a blockchain or hash chain. Part 11 and ALCOA+ ask for trustworthy, attributable, auditable records; chaining is one proposed way to make edits visible.

    Explanation, details and sources

    A cryptographic hash turns any record into a fixed-length digest; changing one character changes the digest. Linking each record's hash to the previous one (Haber and Stornetta, 1991) means that editing an early record breaks every later link unless all later records are recomputed, and recomputing changes the final hash. Sharing that final hash with a customer, or having it time-stamped by an independent authority (RFC 3161), makes a full rewrite detectable. NIST describes blockchains as tamper evident and tamper resistant rather than immutable (NIST IR 8202, 7.1) and notes that a ledger cannot tell whether input data reflect real-world events (7.3).

    For a certificate of analysis, the hash would prove that the document a customer holds matches the one released; it would not prove the analysis was right. Correctness still depends on validated methods, qualified instruments, trained analysts, second-person review and the Part 11 controls above. Proposed use: hash certificates and shipment records at release, publish or share the digest, and treat any correction as a new, linked document (ISO/IEC 17025 7.8.8).

    Planning laboratory data or traceability work?

    EUTECNIQ is in formation. Early conversations help define what a shared data and traceability design should cover.